Vol. 123
Latest Volume
All Volumes
PIER 179 [2024] PIER 178 [2023] PIER 177 [2023] PIER 176 [2023] PIER 175 [2022] PIER 174 [2022] PIER 173 [2022] PIER 172 [2021] PIER 171 [2021] PIER 170 [2021] PIER 169 [2020] PIER 168 [2020] PIER 167 [2020] PIER 166 [2019] PIER 165 [2019] PIER 164 [2019] PIER 163 [2018] PIER 162 [2018] PIER 161 [2018] PIER 160 [2017] PIER 159 [2017] PIER 158 [2017] PIER 157 [2016] PIER 156 [2016] PIER 155 [2016] PIER 154 [2015] PIER 153 [2015] PIER 152 [2015] PIER 151 [2015] PIER 150 [2015] PIER 149 [2014] PIER 148 [2014] PIER 147 [2014] PIER 146 [2014] PIER 145 [2014] PIER 144 [2014] PIER 143 [2013] PIER 142 [2013] PIER 141 [2013] PIER 140 [2013] PIER 139 [2013] PIER 138 [2013] PIER 137 [2013] PIER 136 [2013] PIER 135 [2013] PIER 134 [2013] PIER 133 [2013] PIER 132 [2012] PIER 131 [2012] PIER 130 [2012] PIER 129 [2012] PIER 128 [2012] PIER 127 [2012] PIER 126 [2012] PIER 125 [2012] PIER 124 [2012] PIER 123 [2012] PIER 122 [2012] PIER 121 [2011] PIER 120 [2011] PIER 119 [2011] PIER 118 [2011] PIER 117 [2011] PIER 116 [2011] PIER 115 [2011] PIER 114 [2011] PIER 113 [2011] PIER 112 [2011] PIER 111 [2011] PIER 110 [2010] PIER 109 [2010] PIER 108 [2010] PIER 107 [2010] PIER 106 [2010] PIER 105 [2010] PIER 104 [2010] PIER 103 [2010] PIER 102 [2010] PIER 101 [2010] PIER 100 [2010] PIER 99 [2009] PIER 98 [2009] PIER 97 [2009] PIER 96 [2009] PIER 95 [2009] PIER 94 [2009] PIER 93 [2009] PIER 92 [2009] PIER 91 [2009] PIER 90 [2009] PIER 89 [2009] PIER 88 [2008] PIER 87 [2008] PIER 86 [2008] PIER 85 [2008] PIER 84 [2008] PIER 83 [2008] PIER 82 [2008] PIER 81 [2008] PIER 80 [2008] PIER 79 [2008] PIER 78 [2008] PIER 77 [2007] PIER 76 [2007] PIER 75 [2007] PIER 74 [2007] PIER 73 [2007] PIER 72 [2007] PIER 71 [2007] PIER 70 [2007] PIER 69 [2007] PIER 68 [2007] PIER 67 [2007] PIER 66 [2006] PIER 65 [2006] PIER 64 [2006] PIER 63 [2006] PIER 62 [2006] PIER 61 [2006] PIER 60 [2006] PIER 59 [2006] PIER 58 [2006] PIER 57 [2006] PIER 56 [2006] PIER 55 [2005] PIER 54 [2005] PIER 53 [2005] PIER 52 [2005] PIER 51 [2005] PIER 50 [2005] PIER 49 [2004] PIER 48 [2004] PIER 47 [2004] PIER 46 [2004] PIER 45 [2004] PIER 44 [2004] PIER 43 [2003] PIER 42 [2003] PIER 41 [2003] PIER 40 [2003] PIER 39 [2003] PIER 38 [2002] PIER 37 [2002] PIER 36 [2002] PIER 35 [2002] PIER 34 [2001] PIER 33 [2001] PIER 32 [2001] PIER 31 [2001] PIER 30 [2001] PIER 29 [2000] PIER 28 [2000] PIER 27 [2000] PIER 26 [2000] PIER 25 [2000] PIER 24 [1999] PIER 23 [1999] PIER 22 [1999] PIER 21 [1999] PIER 20 [1998] PIER 19 [1998] PIER 18 [1998] PIER 17 [1997] PIER 16 [1997] PIER 15 [1997] PIER 14 [1996] PIER 13 [1996] PIER 12 [1996] PIER 11 [1995] PIER 10 [1995] PIER 09 [1994] PIER 08 [1994] PIER 07 [1993] PIER 06 [1992] PIER 05 [1991] PIER 04 [1991] PIER 03 [1990] PIER 02 [1990] PIER 01 [1989]
2011-12-20
Experimental Comparison of Remedial Single-Channel Operations for Redundant Flux-Switching Permanent-Magnet Motor Drive
By
Progress In Electromagnetics Research, Vol. 123, 189-204, 2012
Abstract
Redundant flux-switching permanent-magnet (R-FSPM) motor is a new fault-tolerant machine having PMs in the stator, offering high efficiency, high reliability, and robust structure. This paper proposes two remedial control strategies for fault-tolerant operations of the R-FSPM motor drive in the single-channel (SC) mode. First, by doubling the healthy-channel currents, the reduced torque due to one channel loss can be remedied, the so-called remedial brushless AC (BLAC) operation mode. Second, by injecting harmonic current (IHC) considering harmonic back-EMF effect, the reduced torque can also be smoothly remedied, the so-called remedial IHC operation mode. Finally, both of the proposed remedial control strategies are verified by co-simulation and experimentation, hence confirming the validity of the proposed fault-tolerant R-FSPM motor drive.
Citation
Wenxiang Zhao, Ming Cheng, Ruiwu Cao, and Jinghua Ji, "Experimental Comparison of Remedial Single-Channel Operations for Redundant Flux-Switching Permanent-Magnet Motor Drive," Progress In Electromagnetics Research, Vol. 123, 189-204, 2012.
doi:10.2528/PIER11110405
References

1. Liu, C., K. T. Chau, and J. Z. Jiang, "A permanent-magnet hybrid brushless integrated starter-generator for hybrid electric vehicles," IEEE Transactions on Industrial Electronics, Vol. 57, No. 12, 4055-4064, 2010.
doi:10.1109/TIE.2010.2044128

2. El-Refaie, A. M., "Fault-tolerant permanent magnet machines: A review," IET Electric Power Applications, Vol. 5, No. 1, 59-74, 2011.
doi:10.1049/iet-epa.2009.0117

3. Chau, K. T., C. C. Chan, and C. Liu, "Overview of permanent-magnet brushless drives for electric and hybrid electric vehicles," IEEE Transactions on Industrial Electronics, Vol. 55, No. 6, 2246-2257, 2008.
doi:10.1109/TIE.2008.918403

4. Touati, S., R. Ibtiouen, O. Touhami, and A. Djerdir, "Experimental investigation and optimization of permanent magnet motor based on coupling boundary element method with permeances network," Progress In Electromagnetics Research, Vol. 111, 71-90, 2011.
doi:10.2528/PIER10092303

5. Jian, L., G. Xu, J. Song, H. Xue, D. Zhao, and J. Liang, "Optimum design for improving modulating-effect of coaxial magnetic gear using response surface methodology and genetic algorithm," Progress In Electromagnetics Research, Vol. 116, 297-312, 2011.

6. Jack, A. G., B. C. Mecrow, and J. Haylock, "A comparative study of permanent magnet and switched reluctance motors for high-performance fault-tolerant applications," IEEE Transactions on Industry Applications, Vol. 32, No. 4, 889-895, 1996.
doi:10.1109/28.511646

7. Sun, Z., J. Wang, G. Jewell, and D. Howe, "Enhanced optimal torque control of fault-tolerant permanent magnet machines under flux weakening operations," IEEE Transactions on Industrial Electronics, Vol. 57, No. 1, 344-353, 2010.
doi:10.1109/TIE.2009.2038336

8. Parsa, L. and H. A. Toliyat, "Fault-tolerant interior-permanent-magnet machines for hybrid electric vehicle applications," IEEE Transactions on Vehicular Technology, Vol. 56, No. 4, 1546-1552, 2007.
doi:10.1109/TVT.2007.896978

9. Dwari, S. and L. Parsa, "Fault-tolerant control of five-phase permanent magnet motors with trapezoidal back-EMF," IEEE Transactions on Industrial Electronics, Vol. 58, No. 2, 476-485, 2011.
doi:10.1109/TIE.2010.2045322

10. Thomas, A. S., Z. Q. Zhu, and G. W. Jewell, "Comparison of flux switching and surface mounted permanent magnet generators for high-speed applications," IET Electrical Systems in Transportation, Vol. 1, No. 3, 111-116, 2011.
doi:10.1049/iet-est.2010.0049

11. Cheng , M., W. Hua, J. Zhang, and W. Zhao, "Overview of stator-permanent magnet brushless machines," IEEE Transactions on Industrial Electronics, Vol. 58, No. 11, 5087-5101, 2011.
doi:10.1109/TIE.2011.2123853

12. Zhao, W., K. T. Chau, M. Cheng, J. Ji, and X. Zhu, "Remedial brushless AC operation of fault-tolerant doubly-salient permanent-magnet motor drives," IEEE Transactions on Industrial Electronics, Vol. 57, No. 6, 2134-2141, 2010.
doi:10.1109/TIE.2009.2033824

13. Zhang, J., M. Cheng, Z. Chen, and W. Hua, "Comparison of stator-mounted permanent-magnet machines based on a general power equation," IEEE Transactions on Energy Conversion, Vol. 24, No. 4, 826-834, 2009.
doi:10.1109/TEC.2009.2025346

14. Zhu, Z. Q. and J. T. Chen, "Advanced flux-switching permanent magnet brushless machines," IEEE Transactions on Magnetics, Vol. 46, No. 6, 1447-1453, 2010.
doi:10.1109/TMAG.2010.2044481

15. Fei, W., P. C. K. Luk, J. Shen, B. Xia, and Y. Wang, "Permanent-magnet flux-switching integrated starter generator with different rotor configurations for cogging torque and torque ripple mitigations," Transactions on Industry Applications, Vol. 47, No. 3, 1247-1256, 2011.
doi:10.1109/TIA.2011.2125750

16. Zhao, W., M. Cheng, W. Hua, H. Jia, and R. Cao, "Back-EMF harmonic analysis and fault-tolerant control of flux-switching permanent-magnet machine with redundancy," IEEE Transactions on Industrial Electronics, Vol. 58, No. 5, 1926-1936, 2011.
doi:10.1109/TIE.2010.2050758

17. Jian, L. and K. T. Chau, "Design and analysis of a magnetic-geared electronic-continuously variable transmission system using finite element method," Progress In Electromagnetics Research, Vol. 107, 47-61, 2010.
doi:10.2528/PIER10062806

18. Jian, L., G. Xu, G. Yu, J. Song, J. Liang, and M. Chang, "Electro-magnetic design and analysis of a novel magnetic-gear-integrated wind power generator using time-stepping finite element method," Progress In Electromagnetics Research, Vol. 113, 351-367, 2011.

19. Mahmoudi, A., N. A. Rahim, and H. W. Ping, "Axial-flux permanent-magnet motor design for electric vehicle direct drive using sizing equation and finite element analysis," Progress In Electromagnetics Research, Vol. 122, 467-496, 2012.
doi:10.2528/PIER11090402

20. Vaseghi, B., N. Takorabet, and F. Meibody-Tabar, "Transient finite element analysis of induction machines with stator winding turn fault," Progress In Electromagnetics Research, Vol. 95, 1-18, 2009.
doi:10.2528/PIER09052004

21. Torkaman, H. and E. Afjei, "FEM analysis of angular misalignment fault in SRM magnetostatic characteristics," Progress In Electromagnetics Research, Vol. 104, 31-48, 2010.
doi:10.2528/PIER10041406

22. Torkaman, H. and E. Afjei, "Hybrid method of obtaining degrees of freedom for radial airgap length in SRM under normal and faulty conditions based on magnetiostatic model," Progress In Electromagnetics Research, Vol. 100, 37-54, 2010.
doi:10.2528/PIER09111108

23. Ding, W., D. Liang, and H. Sui, "Dynamic modeling and performance prediction for dual-channel switched reluctance machine considering mutual coupling," IEEE Transactions on Magnetics, Vol. 46, No. 9, 3652-3663, 2010.
doi:10.1109/TMAG.2010.2045390