PIERM 126 [2024] PIERM 125 [2024] PIERM 124 [2024] PIERM 123 [2024] PIERM 122 [2023] PIERM 121 [2023] PIERM 120 [2023] PIERM 119 [2023] PIERM 118 [2023] PIERM 117 [2023] PIERM 116 [2023] PIERM 115 [2023] PIERM 114 [2022] PIERM 113 [2022] PIERM 112 [2022] PIERM 111 [2022] PIERM 110 [2022] PIERM 109 [2022] PIERM 108 [2022] PIERM 107 [2022] PIERM 106 [2021] PIERM 105 [2021] PIERM 104 [2021] PIERM 103 [2021] PIERM 102 [2021] PIERM 101 [2021] PIERM 100 [2021] PIERM 99 [2021] PIERM 98 [2020] PIERM 97 [2020] PIERM 96 [2020] PIERM 95 [2020] PIERM 94 [2020] PIERM 93 [2020] PIERM 92 [2020] PIERM 91 [2020] PIERM 90 [2020] PIERM 89 [2020] PIERM 88 [2020] PIERM 87 [2019] PIERM 86 [2019] PIERM 85 [2019] PIERM 84 [2019] PIERM 83 [2019] PIERM 82 [2019] PIERM 81 [2019] PIERM 80 [2019] PIERM 79 [2019] PIERM 78 [2019] PIERM 77 [2019] PIERM 76 [2018] PIERM 75 [2018] PIERM 74 [2018] PIERM 73 [2018] PIERM 72 [2018] PIERM 71 [2018] PIERM 70 [2018] PIERM 69 [2018] PIERM 68 [2018] PIERM 67 [2018] PIERM 66 [2018] PIERM 65 [2018] PIERM 64 [2018] PIERM 63 [2018] PIERM 62 [2017] PIERM 61 [2017] PIERM 60 [2017] PIERM 59 [2017] PIERM 58 [2017] PIERM 57 [2017] PIERM 56 [2017] PIERM 55 [2017] PIERM 54 [2017] PIERM 53 [2017] PIERM 52 [2016] PIERM 51 [2016] PIERM 50 [2016] PIERM 49 [2016] PIERM 48 [2016] PIERM 47 [2016] PIERM 46 [2016] PIERM 45 [2016] PIERM 44 [2015] PIERM 43 [2015] PIERM 42 [2015] PIERM 41 [2015] PIERM 40 [2014] PIERM 39 [2014] PIERM 38 [2014] PIERM 37 [2014] PIERM 36 [2014] PIERM 35 [2014] PIERM 34 [2014] PIERM 33 [2013] PIERM 32 [2013] PIERM 31 [2013] PIERM 30 [2013] PIERM 29 [2013] PIERM 28 [2013] PIERM 27 [2012] PIERM 26 [2012] PIERM 25 [2012] PIERM 24 [2012] PIERM 23 [2012] PIERM 22 [2012] PIERM 21 [2011] PIERM 20 [2011] PIERM 19 [2011] PIERM 18 [2011] PIERM 17 [2011] PIERM 16 [2011] PIERM 14 [2010] PIERM 13 [2010] PIERM 12 [2010] PIERM 11 [2010] PIERM 10 [2009] PIERM 9 [2009] PIERM 8 [2009] PIERM 7 [2009] PIERM 6 [2009] PIERM 5 [2008] PIERM 4 [2008] PIERM 3 [2008] PIERM 2 [2008] PIERM 1 [2008]
2018-10-14
The Ionized Field Calculation Under Different Haze Weather Levels Based on Improved Upstream Meshless Method
By
Progress In Electromagnetics Research M, Vol. 74, 147-157, 2018
Abstract
The haze-prone areas are usually places with limited transmission line corridors and large power loads. The performance of transmission lines is under threat of haze. The haze particulates around the transmission lines would be charged and affect the electric field near high voltage direct current (HVDC) transmission lines. Accoring to the influence mechanism of haze on ionized field, the electric perfromance of HVDC transmission lines under haze weather is dicussed. In the paper, an improved meshless local Petrov-Galerkin method (MLPG) is proposed to investigate the distribution of ionized electric field, and example of an actual transmission line is studied to verify the validation of the proposed method at first. It is proved that the proposed method agrees well with the measurements. Then the ionized field distribution under different haze weather levels is discussed, as well as the influenced factor. Results indicate that the ionized electric field and ion current density on the ground would increase under haze weather, but with the similar trends to good weather condition. Meanwhile, the haze weather levels have greater influence on the ionized electric field than ion current density, where the increase of corona and space charge are the main reasons.
Citation
Bing Gao, Fan Yang, Haizhou Qian, Min Liu, Chunli Li, and Chao Liu, "The Ionized Field Calculation Under Different Haze Weather Levels Based on Improved Upstream Meshless Method," Progress In Electromagnetics Research M, Vol. 74, 147-157, 2018.
doi:10.2528/PIERM18031205
References

1. Lu, T., H. Feng, X. Cui, et al. "Analysis of the ionized field under HVDC transmission lines in the presence of wind based on upstream finite element method," IEEE Transactions on Magnetics, Vol. 46, No. 8, 2939-2942, 2011.
doi:10.1109/TMAG.2010.2044149

2. Su, H., Z. Jia, Z. Sun, et al. "Field and laboratory tests of insulator flashovers under conditions of light ice accumulation and contamination," IEEE Transactions on Dielectrics & Electrical Insulation, Vol. 19, No. 5, 1681-1689, 2012.
doi:10.1109/TDEI.2012.6311516

3. Fu, J., Y. Hui, W. Chen, et al. "The research on influence law of different environment on the ion flow field of HVDC transmission line and insulator contamination," Industrial Electronics and Applications, 310-314, IEEE, 2016.

4. Zhang, Z., D. Zhang, X. Jiang, et al. "Study on natural contamination performance of typical types of insulators," IEEE Transactions on Dielectrics & Electrical Insulation, Vol. 21, No. 4, 1901-1909, 2014.
doi:10.1109/TDEI.2014.004343

5. Maruvada, P. S., "Electric field and ion current environment of HVDC transmission lines: Comparison of calculations and measurements," IEEE Trans. Power Delivery, Vol. 27, No. 1, 401-410, 2012.
doi:10.1109/TPWRD.2011.2172003

6. Comber, M. G. and G. B. Johnson, "HVDC field and ion effects research at project UHV: Results of electric field and ion current measurement," IEEE Transactions on Power Apparatus and Systems, Vol. 101, No. 7, 1998-2006, 1982.
doi:10.1109/TPAS.1982.317447

7. Johnson, G. B., "Electric fields and ion currents of a ±400 kV HVDC test line," IEEE Transactions on Power Apparatus and Systems, Vol. 102, No. 8, 2559-2568, 1983.
doi:10.1109/TPAS.1983.317775

8. Fan, Y., Z. H. Liu, et al. "Calculation of ionized field of HVDC transmission lines by the meshless method," IEEE Transactions on Magnetics, Vol. 50, No. 7, 1-6, 2014.

9. Lu, F., Q. Z. Ye, F. C. Lin, et al. "Effects of raindrops on ion flow field under HVDC transmission lines," Proceedings of the CSEE, Vol. 30, No. 7, 125-130, 2010.

10. Zhao, Y. and W. Zhang, "Effects of fog on ion flow field under HVDC transmission lines," Proceedings of the CSEE, Vol. 33, No. 13, 194-199, 2013.

11. Fonseca Alexandre, R., C. Correa Bruno, J. Silva Elson, et al. "Improving the mixed formulation for meshless local Petrov-Galerkin method," IEEE Transactions on Magnetics, Vol. 46, No. 08, 2907-2910, 2010.
doi:10.1109/TMAG.2010.2043513

12. Qiao, J., J. Zou, J. S. Yuan, et al. "A new finite difference based approach for calculating ion flow field of HVDC transmission lines," Transactions of China Electrotechnical Society, Vol. 30, No. 6, 185-191, 2015.

13. Huang, G., J. Ruan, Z. Du, and C. Zhao, "Highly stable upwind FEM for solving ionized field of HVDC transmission line," IEEE Transactions on Magnetics, Vol. 48, No. 2, 719-722, 2012.
doi:10.1109/TMAG.2011.2174203

14. Li, H. L., "Research on the concentration and size distribution of indoor suspended particulates matters,", Huazhong University of Science and Technology, 2009.

15. Niu, H. and T. Xu, "The relevance between dramatic declines of air gap breakdown voltage and fog-haze weather," TENCON 2015 — 2015 IEEE Region 10 Conference, IEEE, 2016.