EXPERIMENTAL REALIZATION OF STRONG DC MAGNETIC ENHANCEMENT WITH TRANSFORMATION OPTICS (Invited Paper)

By K. Liu, W. Jiang, F. Sun, and S. He

Full Article PDF (583 KB)

Abstract:
A passive DC magnetic concentrator is designed with transformation optics (TO) and realized by meta-materials. The passive DC magnetic concentrator, based on space compression transformation, can greatly enhance the magnetic field in a free space region, which can be used for e.g. improving the sensitivity of magnetic sensors and increasing the efficiency of wireless energy transmission. The magnetic property of the medium obtained by TO is extremely anisotropic. To solve this, we use magnetic meta-materials made of alternated high-permeability ferromagnetic (HPF) materials and high-temperature superconductor (HTS) materials. We optimize our structure by conducting simulations using the finite element method (FEM), and experimentally demonstrate a strong, 4.74-time enhancement of the DC magnetic field by our meta-material magnetic concentrator. We also demonstrate that a simplified structure with only HPF materials working at room temperature could still give 3.84-time enhancement of the DC magnetic field. The experimental results are in good agreement with the numerical simulations based on FEM.

Citation:
K. Liu, W. Jiang, F. Sun, and S. He, "Experimental Realization of Strong DC Magnetic Enhancement with Transformation Optics (Invited Paper)," Progress In Electromagnetics Research, Vol. 146, 187-194, 2014.
doi:10.2528/PIER14042704
http://www.jpier.org/PIER/pier.php?paper=14042704

References:
1. Ripka, P. and M. Janosek, "Advances in magnetic field sensors," IEEE Sens. J., Vol. 10, No. 6, 1108-1116, 2010.

2. Kurs, A., A. Karalis, R. Mo®att, J. D. Joannopoulos, P. Fisher, and M. Soljacic, "Wireless power transfer via strongly coupled magnetic resonances," Science, Vol. 317, No. 5834, 83-86, 2007.

3. Brown, M. A. and R. C. Semelka, MRI: Basic Principles and Applications, Wiley-Blackwell, 2010.

4. Veiseh, O., J. W. Gunn, and M. Zhang, "Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging," Advanced Drug Delivery Reviews, Vol. 62, No. 3, 284-304, 2010.

5. Dobson, J., "Magnetic micro- and nano-particle-based targeting for drug and gene delivery," Nanomedicine, Vol. 1, No. 1, 31-37, 2006.

6. National High Magnetic Field Laboratory, http://www.magnet.fsu.deu/usershub/scientificdivisions/dcfield/facilities.html, .

7. Iwasa, Y., "Hybrid magnets: A magnet engineer's experience and a proposal for the next generation of hybrids," Physica B, Vol. 216, No. 3-4, 1996.

8. Kiyoshi, T., S. Choi, S. Matsumoto, T. Asano, and D. Uglietti, "Magnetic flux concentrator using Gd-Ba-Cu-O bulk superconductors," IEEE Transactions on Applied Superconductivity, Vol. 19, No. 3, 2174-2177, 2009.

9. Zhang, Z. Y., S. Choi, S. Matsumoto, R. Teranshi, G. Giunchi, A. F. Albisetti, and T. Kiyoshi, "Magnetic lenses using different MgB2 bulk superconductors," Supercond. Sci. Technol., Vol. 25, No. 2, 025009, 2012.

10. Leonhardt, U. and T. G. Philbin, Geometry and Light: Science of Invisibility, Dover, 2010.

11. Pendry, J. B., D. Schurig, and D. R. Smith, "Controlling electromagnetic fields," Science, Vol. 312, No. 5781, 1780-1782, 2006.

12. Pendry, J. B., "Negative refraction makes a perfect lens," Physical Review Letters, Vol. 85, No. 18, 3966-3969, 2000.

13. Schurig, D., J. J. Mock, B. J. Justice, S. A. Cummer, J. B. Pendry, A. F. Starr, and D. R. Smith, "Metamaterial electromagnetic cloak at microwave frequencies," Science, Vol. 314, No. 5801, 977-980, 2006.

14. Yang, F., Z. L. Mei, T. Y. Jin, and T. J. Cui, "DC electric invisibility cloak," Physical Review Letters, Vol. 109, 053902, 2012.

15. Gomory, F., M. Solovyov, J. ·Souc, C. Navau, J. Prat-Camps, and A. Sanchez, "Experimental realization of a magnetic cloak," Science, Vol. 335, No. 6075, 1466-1468, 2012.

16. Narayana, S. and Y. Sato, "DC magnetic cloak," Advanced Materials, Vol. 24, No. 1, 71-74, 2012.

17. Navau, C., J. Prat-Camps, and A. Sanchez, "Magnetic energy harvesting and concentration at a distance by transformation optics," Physical Review Letters, Vol. 109, 263903, 2012.

18. Sun, F. and S. He, "Create a uniform static magnetic field over 50T in a large free space region," Progress In Electromagnetics Research, Vol. 137, 149-157, 2013.

19. Sun, F. and S. He, "Static magnetic field concentration and enhancement using magnetic materials with positive permeability," Progress In Electromagnetics Research, Vol. 142, 579-590, 2013.

20. Sun, F. and S. He, "DC magnetic concentrator and omnidirectional cascaded cloak by using only one or two homogeneous anisotropic materials of positive permeability," Progress In Electromagnetics Research, Vol. 142, 683-699, 2013.

21. Prat-Camps, J., C. Navau, and A. Sanchez, "Experimental realization of magnetic energy concentration and transmission at distance by metamaterials,", arXiv: 1308.5878, 2013.

22. Rahm, M., D. Schurig, D. A. Roberts, S. A. Cummer, D. R. Smith, and J. B. Pendry, "Design of electromagnetic cloak and concentrators using form-invariant coordinate transformations of Maxwell's equations," Photonics and Nanostructures-fundamentals and Applications, Vol. 6, 87-95, 2008.

23. Li, W., J. Guan, and W. Wang, "Homogeneous-materials-constructed electromagnetic field concentrators with adjustable concentrating ratio," J. Phys. D: Appl. Phys., Vol. 44, 125401, 2011.

24. The Finite Element Simulation is Conducted by Using Commercial Software COMSOL Multiphysics, http://www.comsol.com, .

25. Rupich, M. W., X. Li, S. Sathyamurthy, C. L. H. Thieme, K. DeMoranville, J. Gannon, and S. Fleshler, "Second generation wire development at AMSC," IEEE Transactions on Applied Superconductivity, Vol. 23, No. 3, 6601205, 2013.


© Copyright 2014 EMW Publishing. All Rights Reserved