2012-03-30
An Interpolation Method to Calibrate Electromagnetic Probes in Semi-Anechoic Chambers
By
Progress In Electromagnetics Research B, Vol. 39, 355-371, 2012
Abstract
Based upon the standard IEEE 1309, a new calibration method for electromagnetic (EM) probes is proposed. The aforementioned method compares the electric field strength measured with the EM probe subject to calibration with the E-field intensity calculated through a linear interpolation of the corrected measurement using a reference EM probe. The corrected measurement results are computed by means of the calibration factors stated in the calibration certificate of the reference EM probe. The conditions and criteria under which it is possible to calibrate EM probes inside semi-anechoic chambers in the frequency range of 80 MHz to 1 GHz, are presented. The results shows that the calibration method proposed in this paper is characterized by deviations of less than 1 dB in almost all the frequencies considered, verifying the reliability of the method. The proposed approach is very useful for registering the measurement drift of EM probes used in EMC testing laboratories.
Citation
Ciro Tremola, Marco A. Azpurua, Eduardo Paez, Daniel Ormeno, and Alejandro Rebolledo, "An Interpolation Method to Calibrate Electromagnetic Probes in Semi-Anechoic Chambers," Progress In Electromagnetics Research B, Vol. 39, 355-371, 2012.
doi:10.2528/PIERB12012604
References

1. ICNIRP Guidelines "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz). International commission on non-ionizing radiation protection," Health Physics, Vol. 74, No. 4, 494-522, 1998.        Google Scholar

2. IEC 61000-4-3 "Testing and measurement techniques radiated, radio-frequency, electromagnetic field immunity test --- Electro-magnetic compatibility (EMC), Part 4-3," International Electrotechnical Commission (IEC), Edition 3.2, Apr. 2010.

3. IEEE 1309 "IEEE standard for calibration of electromagnetic field sensors and probes, excluding antennas, from 9 kHz to 40 GHz," IEEE Electromagnetic Compatibility Society, Jun. 1996.        Google Scholar

4. Nahma, N. S., M. Kanda, E. Larsen, and M. Crawford, "Methodology for standard electromagnetic field measurements," IEEE Transactions on Instrumentation and Measurement, Vol. 34, No. 4, 490-503, 1985.
doi:10.1109/TIM.1985.4315390        Google Scholar

5. Kanda, M., E. Larsen, M. Borsero, P. G. Galliano, I. Yokoshima, and N. Nahman, "Standard for electromagnetic field measurement," Proceedings of the IEEE, Vol. 74, No. 1, 120-128, 1986.
doi:10.1109/PROC.1986.13418        Google Scholar

6. De Vreede, J. P. M., G. M. Teunisse, K. Munter, H. Hoitink, K. Holland, M. O'Dwyer, L. Bergsten, and L. Puranen, "Calibration of RF field strength meters," IEEE Transactions on Instrumentation and Measurement, Vol. 44, No. 2, 351-355, 1995.
doi:10.1109/19.377850        Google Scholar

7. Ishigami, S. and H. Masayuki, "A new calibration method for an electric-field probe using TEM waveguides," Proceedings of 20th Int. Zurich Symposium on EMC, 425-428, 2009.        Google Scholar

8. NG, K. T., T. E. Batchman, S. Pavlica, and D. L. Veasey, "Amplification and calibration for miniature E-field probes," IEEE Transactions on Instrumentation and Measurement, Vol. 37, No. 3, 434-438, 1988.
doi:10.1109/19.7470        Google Scholar

9. Gao, Y., A. Lauer, Q. Ren, and I. Wolff, "Calibration of electric coaxial near-field probes and applications," IEEE Transactions on Microwave Theory and Techniques, Vol. 46, No. 11, 1694-1702, 1998.
doi:10.1109/22.734563        Google Scholar

10. Kang, N.-W., J.-S. Kang, D.-C. Kim, J.-H. Kim, and J.-G. Lee, "Characterization method of electric field probe by using transfer standard in GTEM cell," IEEE Transactions on Instrumentation and Measurement, Vol. 58, No. 4, 1109-1113, 2009.
doi:10.1109/TIM.2008.2008592        Google Scholar

11. Munter, K., "Portable E-field strength meter and its traceable calibration up to 1 GHz using a G-TEM cells," IEEE Transactions on Instrumentation and Measurement, Vol. 46, No. 2, 549-550, 1997.
doi:10.1109/19.571908        Google Scholar

12. ANSI 63.4 "American national standard for methods of measurement of radio-noise emissions from low-voltage electrical and electronic equipment in the range of 9 kHz to 40 GHz," American National Standards Institute (ANSI), Jan. 2004.        Google Scholar

13. CISPR 16-1-4 "Specification for radio disturbance and immunity measuring apparatus and methods --- Part 1--4: Radio disturbance and immunity measuring apparatus --- Antennas and test sites for radiated disturbance measurements," International Electrotechnical Commission (IEC), 3rd edition, 2010.        Google Scholar

14. Betta, G., D. Capriglione, C. F. M. Carobbi, and M. D. Migliore, "Calibration of antenna for EMI measurements in compact semi-anechoic rooms," 16th IMEKO TC4 Symposium, 2008.        Google Scholar

15. Valdman, C., M. H. Dias, and J. C. A. Santos, "Design and calibration of electric field probe to the frequency range of 2 to 3 GHz," IEEE Latin America Transactions, Vol. 6, No. 7, 557-563, 2008.
doi:10.1109/TLA.2008.4917425        Google Scholar

16. Komakine, T., T. Kurosawa, and H. Inoue, "A novel method of electric field estimation by using spherical dielectric scatterer," IEEJ Transactions on Fundamentals and Materials, Vol. 130, No. 5, 462-466, 2010.
doi:10.1541/ieejfms.130.462        Google Scholar

17. Guide NPL A Guide to Power Flux Density and Field Strength Measurement, 1st Ed., The Institute of Measurement and Control, National Physical Laboratory (NPL), 2004.

18. Páez, E., C. Tremola, and M. Azpúrua, "A proposed method for quantifying uncertainty in RF inmunity testing due to EUT presence," Progress In Electromagnetics Research B, Vol. 29, 175-190, 2011.
doi:10.2528/PIERB11020802        Google Scholar

19. Ifong, W., S. Ishigami, K. Gotoh, and Y. Matsumoto, "Probe calibration by using a different type of probe as a reference in GTEM cell above 1 GHz," IEICE Electronic Express, Vol. 7, No. 6, 460-466, 2010.
doi:10.1587/elex.7.460        Google Scholar

20. Chen, S. and J-S. Yuan, "Adaptive gate bias for power amplifier temperature compensation," IEEE on Device and Materials Reliability, Vol. 11, No. 3, 442-449, 2011.
doi:10.1109/TDMR.2011.2160264        Google Scholar

21. Gómez, D., M. Sroka, and J. Jiménez, "Process and temperature compensation for RF low noise amplifiers and mixers," IEEE Transactions on Circuits and Systems I: Regular Papers, 1204-1211, 2010.
doi:10.1109/TCSI.2009.2031707        Google Scholar

22. Mann, M., B. Gutheil, J. Zastrau, and P. Weiss, "Electromagnetic field measurements --- Means of verification," Proceeding of the 5th WSEAS/IASME, 591-595, 2005.        Google Scholar

23. Mann, M., H. Bruggemeyer, and P. Weiss, "Verification of electromagnetic field measurements via inter-laboratory comparison measurements," Advances in Radio Science, No. 3, 83-89, 2005.
doi:10.5194/ars-3-83-2005        Google Scholar

24. Stratakis, D., A. Miaoudakis, C. Katsidis, V. Zacharopoulos, and T. Xenos, "On the uncertainty estimation of electromagnetic field measurements using field sensors: A general approach," Radiation Protection Dosimetry, 1-8, 2009.        Google Scholar

25. Alexander, M. J., M. J. Salter, D. G. Gentle, D. A. Knight, B. G. Loader, and K. P. Holland, Measurement good practice guide N 73: Calibration and use of antennas, focusing on EMC applications, National Physical Laboratory (NPL), 2004.

26. Chen, Z., "Practical considerations for radiated immunities measurement using ETS-lindgren EMC probes," ETS-Lindgren White Paper, 2011, Available at: http://www.ets-lindgren.com/page/?i=WhitePaper-ETSL0511.