2020-01-07
Thermography at Millimetre Wavelengths for Security Inspection of Footwear
By
Progress In Electromagnetics Research M, Vol. 88, 83-89, 2020
Abstract
Millimetre-wave thermography is used to image through the soles of shoes as proof of principle study into the application of such an approach for security inspection. Current airport security screening practice necessitates the removal of shoes prior to x-ray screening for potential threats or other concealments, for example explosive or explosive precursor materials; narcotic substances or small weapons. The authors demonstrate that thermography at ~250 GHz is able to reveal a variety of objects concealed within the soles of typical shoes, and that such an approach might be applied to rapidly screen passengers without necessitating the removal of their footwear.
Citation
Stuart William Harmer, Christopher I. Johnson, Dana E. Wheeler, and Hashim Bhabha, "Thermography at Millimetre Wavelengths for Security Inspection of Footwear," Progress In Electromagnetics Research M, Vol. 88, 83-89, 2020.
doi:10.2528/PIERM19100602
References

1. Appleby, R. and R. N. Anderton, "Millimeter-wave and submillimeter-wave imaging for security and surveillance," Proceedings of the IEEE, Vol. 95, No. 8, 1683-1689, Aug. 2007.
doi:10.1109/JPROC.2007.898832        Google Scholar

2. Appleby, R. and H. B. Wallace, "Standooff detection of weapons and contraband in the 100 GHz to 1THz region," IEEE Transactions on Antennas and Propagation, Vol. 55, 2944-2956, 2007.
doi:10.1109/TAP.2007.908543        Google Scholar

3. Kemp, M. C., "Millimetre wave and terahertz technology for the detection of concealed threats — A review," Proceedings of SPIE, Vol. 6402, 2006.        Google Scholar

4. Agurto, A., Y. Li, G. Tian, N. Bowring, and S. Lockwood, "A review of concealed weapon detection and research in perspective," Proc. IEEE Int. Conf. MonE02 Networking, Sensing and Control, 443-448, 2007.        Google Scholar

5. Salmon, N. A., "W-band real-time passive millimeter-wave imager for helicopter collision avoidance," Proc. SPIE, Vol. 3703, 28-32, Apr. 1999.
doi:10.1117/12.353007        Google Scholar

6. Owda, A. Y., N. Salmon, S. W. Harmer, S. Shylo, N. J. Bowring, N. D. Rezgui, and M. Shah, "Millimeter-wave emissivity as a metric for the non-contact diagnosis of human skin conditions," Bioelectromagnetics, Vol. 38, 559-569, 2017.
doi:10.1002/bem.22074        Google Scholar

7. Harmer, S. W., S. Shylo, M. Shah, N. J. Bowring, and A. Y. Owda, "On the feasibility of assessing burn wound healing without removal of dressings using radiometric millimetre-wave sensing," Progress In Electromagnetics Research M, Vol. 45, 173-183, 2016.
doi:10.2528/PIERM15110503        Google Scholar

8. Mann, C., "First demonstration of a vehicle mounted 250 GHz real time passive images," Proc. SPIE, Vol. 7311, 73110Q-1-73110Q-7, May 2009.        Google Scholar

9. Appleby, R., P. Coward, and J. N. Sanders-Reed, "Evaluation of a passive millimeter wave (PMMW) imager for wire detection in degraded visual conditions," Proc. SPIE, Vol. 7309, 73090A-1-73090A-8, Apr. 2009.        Google Scholar

10. Waldschmid, C., E. Topak, J. Hasch, R. Schnabel, R. Weigel, and T. Zwick, "Millimeter-wave technology for automotive radar sensors in the 77 GHz frequency band," IEEE Transactions on Microwave Theory and Techniques, Vol. 60, No. 3, 845-860, Mar. 2012.
doi:10.1109/TMTT.2011.2178427        Google Scholar

11. Singh, S., "Explosives detection systems (EDS) for aviation security," Signal Processing, Vol. 83, No. 1, 31-55, 2003.
doi:10.1016/S0165-1684(02)00391-2        Google Scholar

12. Lamb, J. W., "Miscellaneous data on materials for millimetre and submillimetre optics," International Journal of Infrared and Millimeter Waves, Vol. 17, No. 12, 1997-2034, Dec. 1996.
doi:10.1007/BF02069487        Google Scholar

13. Yujiri, L., M. Shoucri, and P. Moffa, "Passive millimeter-wave imaging," IEEE Microwave Magazine, Vol. 4, No. 3, 39-50, 2003.
doi:10.1109/MMW.2003.1237476        Google Scholar

14. Goodman, J. W., Introduction to Fourier Optics, McGraw Hill, Jan. 2005.

15. Sinclair, G. N., R. N. Anderton, and R. Appleby, "Outdoor passive millimetre wave security screening," Proc. IEEE 35 Annual 2001 International Carnahan Conference on Security Technology, Oct. 2001.        Google Scholar

16. Prasad, B. S., K. A. Prabha, and P. V. S. G. Kumar, "Condition monitoring of turning process using infrared thermography technique — An experimental approach," Infrared Phys. Technol., Vol. 81, 137-147, Mar. 2015.        Google Scholar

17. Dietlein, C. R., E. Grossman, F. G. Meyer, X. Shen, and Z. Popovic, "Detection and segmentation of concealed objects in terahertz images," IEEE Transactions on Image Processing, Vol. 17, No. 12, Dec. 2008.        Google Scholar

18. Andrews, D. A., D. O’Reilly, M. J. Southgate, N. D. Rezgui, N. J. Bowring, and S. W. Harmer, "Development of an ultra-wide band microwave radar-based footwear scanning system," Proc. SPIE Security + Defence, Vol. 8900, Oct. 2013.        Google Scholar